So after some playing around i think i am satisfied it works and does shut off the flow to the load. Although i am a bit puzzled by when it does it. TBH was a bit paranoid about draining the leisure batteries.
I had the user defined algorithm 1 set, with off < 12.7V and on > 13.01V.
To try it out we "went out for a cup of tea" took our 900w kettle and brewed up , that used 9% of the delta 3 (although i did fill the kettle when there was no need). The ecoflow immediately demanded power and the controller delivered it. The panels were doing about 120W, although when i got a photo it was 69W.
View attachment 135278
What i dont understand is why the controller didnt switch off the load given vBatt was showing 11.98, was it because of the incoming solar ?
either way it did switch off see below. and didnt take long to fill the ecoflow about 30 mins, By the time we got home the leisure batteries were in float.
View attachment 135279
Hopefully someone can explain ! But still well pleased with the Delta 3, the missus can have hot water without using gas and we now have the option to use our low power twin induction hob.